Metal Column Covers
DESCRIPTION   Structural columns of all materials, shapes and sizes, e.g. metal, concrete, round, square, etc. can be covered with stainless steel or aluminum column covers for lasting beauty, or aesthetic reasons. They can also be used to conceal piping, electrical conduit and other services being run within column spaces (with oroper access if necessary). Metal column covers also offer protection against wear, durability, and savings in both maintenance time and costs. 
     
Basic Use:
Exterior or interior
New construction or renovation
Commercial and other applications
May be used over square, round, rectangular or angular columns made of steel, concrete, masonary, wood or other materials.
may be combined with other materials e.g. marble, granite, tile, etc.

Limitations: For non-structural (non-load bearing) use only.

Composition and
Materials
Composition and Materials: Solid 1.5 mm (.062") Type 304 stainless steel or up to 3 mm 9.125") aluminum is used to fabricate Kanalco column covers. Materials coming from the mill in sheet form are finished to customer specifications, covered with strippable, protective plastic film and then formedand fabricated as required.

Flat metal is brake formed; curved or rounded colum covers are either brake or roll formed, depending on radius or direction of curve. Covers can be supplied in 1/2 circle, 1/4 circle or other configuration if desired.

Column covers can be fluted vertically or horizontally as desired, for design effect and/or to facilitate installation, as well as insulated where columns are located at mid-exterior wall (half inside, half outside). Snap-in flute inserts can be provided in a range of colours, or matching finishes.

Using internal members is the most common method of stiffining and fastening of column covers. Requirements for these members e.g. supports, fastening angles, alignment bars, subgirts, brackets, clips, inserts, shims, etc. depend largely on the size and shape of the column. Generally galvanized steel is used f

Finishes: The following aluminum finishes are offered as standard by Kanalco:

Stainless Steel:
1. X-L Blend "S" (Excelsior) - for typical architectural applications.
2. X-L Buff (AISI #8) - for a mirror-like appearance.
3. No. 4 (Excelsior) brushed finish. Other finishes available upon request.

Aluminum:
1. AA-A31 adonized Class 1, 18 um (.0007") or class 2, 10 um (.0004") finish in clear or range of manufacturer's standard architectural colours.
2. Duranar® fluoro-polymer enamel coating with Kynar 500* resin in a wide range of architectural colors.

® Duranar is a registered trademark of PPG Industries, Inc.
* Kynar 500 is a registered trademark of Pennwalt Corporation.


Accessories 1. Galvanized steel brackets or supports as detailed or required.
2. Glass fibre insulation of thickness, density and thermal value as required.
3. Snap-in flute inserts in accent colours, or matching finish.

Sizes: Section widths or round column radius: as desired
Length: (in one piece - 3.6 m (12'-0")(in sections - unlimited)

Thickness:
Stainless Steel - 1.5 mm (.062") is standard. Other thicknesses available.
Aluminum - 3mm (.125") is standard. Other thicknesses available.
Radiused Corners - 6 mm (1/4") minimum

Shapes: Brake or roll (roller die) forming can produce round, square or rectangular, angular or other shapes as desired. Kanalco can advise on proposed design configurations upon request.

Applicable
Standards:
Kanalco metal fabrications conform to:
ASTM A240 for Type 304 stainless steel.
Aluminum Association Designation System for Aluminum Finishes.
AAMA (Architectural Aluminum Manufacturers Association) 605 test requirements for finishes.
CSA G164-M 1981 or ASTM A123-84 for galvanizing of steel brackets or supports, etc.
CSA W59-1989 for corner or other type welds.

TECHNICAL
DATA
Consult with Kanalco Ltd.

INSTALLATION Methods: Kanalco Ltd. are a custom manufacturer specializing in the metal fabrications field. Installation of Kanalco stainless steel and aluminum products is normally carried out by the appropriate trades and experienced installers according to specifications and approved shop drawings.

AVAILABILITY
& COSTS
Kanalco fabricated metal products can be shipped anywhere in North America. Current cost data is available upon request.

WARRANTY Normal 1 year construction warranty.

MAINTENANCE For stainless steel and aluminum finishes, in most instances, only a periodic warm water wash and drying with a soft cloth is sufficient to restore the original lustre.

However, depending on the severity of dirt accumulation, more elaborate cleaning procedures may be required. Consult with Kanalco for additional data.

In the case of mirror-like stainless steel finishes, e.g. X-L Buff, the foregoing is still applicable however commercial creams are available which provide added lustre to these finishes.

TECHNICAL
SERVICES
Kanalco Ltd. can provide consultation from preliminary design through to product application, including the following:

Technical advice for both new work and retrofit applications.
Finish samples.
Specification assistance.
Shop drawings.
Recommending contractor sources.
Site advice and recommendations

RELATED REFERENCES Additional Kanalco Ltd. MANU-DATA technical literature:

- Stainless Steel Wall Panels
- Aluminum Wall Panels
- Speciality Sheet Metal Fabrication - Insulated Panels

SPECIFICATION
SPEC NOTE: The following material and fabrication clauses are arranged for inclusion in the "Sheet Metal Fabrications" or "Manufactured Wall Panels" specification Sections using the CSC/CSI 3-Part Section Format. Square brackets [ ] indicate alternatives, data required or need for the specifier to make a decision.

1 MATERIALS

Column Covers Preformed [stainless steel] [aluminum] column covers as manufactured by Kanalco Ltd. and as follows:

A) Stainless Steel: Type 304 to ASTM A240, [1.5 mm (.062")] thick with [X-L Blend "S" (Excelsior)] [X-L Buff (AISI #8)] [#4(Excelsior)] finish .


B) Aluminum: [_____] alloy aluminum sheet to AA and AAMA requirements, 3mm (.125") thick, with architectural [Class 1, 18 um (.0007")] [Class 2, 10 um (.0004)] [clear anodized] [color anodized] AA-A31 finish [_____color as selected.]

OR

Kynar 500 finish [_____]color as selected. C) Screws: stainless steel to CSA B35.3-1962.

D) Gaskets: closed cell polyurethane foam, adheasive on two sides, release paper protected.

E) Sealents: in accordance with Section 07 [_____], paragraph [_____], [_____] colour selected by [Consultant] [Engineer].

F) Isolation coating: [alkali resistant] [bituminous paint] [epoxy resin solution].

G) Galvanized steel brackets, liner sheet, etc.: hot dipped galvanizing [600] g/m2 [(3.4 mils)] to CSA G164-M1981 or ASTM A123-84.

H) Insulation: glass fibre, density [_____kg/m3 (_____psf)], flame spread [25], permeance 28.75 lvanizing ng/(Pa.s.m2) (_____perms), [RSI-(R)] indicated. with z

J) Insulation adheasive: compatible with type of insulation and [zinc coated steel], uncombustible after curing. g [0] g/m

.2 FABRICATION

1 Fabricate wall panels in accordance with specifications and approved shop drawings.

2 Maximum allowable fabrication tolerences to be:
A) Panel bow: 0.2% of panel dimensions up to 0.187" maximum.

B) Width or length: + 0.80 mm (0.032") up to 1220 mm (48") + 1.5 mm (0.064") from 1220 mm to 3360 mm (48" to 144").

C) Squreness: Maximum 4.7 mm (0.187") difference between diagonal measurements.

3 Form all panels to specified dimensions with tolerences to accomodate thermal expansion and contraction between panels and structural members. Accurately form radii of curved panels in plant.

4 Factory fabricate accessory and trim components, ready for installation.