| DESCRIPTION |
Structural columns of all materials, shapes and sizes, e.g.
metal, concrete, round, square, etc. can be covered with stainless steel or
aluminum column covers for lasting beauty, or aesthetic reasons. They can also
be used to conceal piping, electrical conduit and other services being run
within column spaces (with oroper access if necessary). Metal column covers
also offer protection against wear, durability, and savings in both maintenance
time and costs. |
| Basic Use: |
 |
Exterior
or interior |
 |
New
construction or renovation |
 |
Commercial
and other applications |
 |
May be
used over square, round, rectangular or angular columns made of steel,
concrete, masonary, wood or other materials. |
 |
may be
combined with other materials e.g. marble, granite, tile, etc.
|
|
| Limitations: |
For
non-structural (non-load bearing) use only.
|
Composition and Materials |
Composition and Materials: Solid 1.5 mm (.062") Type 304
stainless steel or up to 3 mm 9.125") aluminum is used to fabricate Kanalco
column covers. Materials coming from the mill in sheet form are finished to
customer specifications, covered with strippable, protective plastic film and
then formedand fabricated as required.
Flat metal is brake formed; curved or rounded colum
covers are either brake or roll formed, depending on radius or direction of
curve. Covers can be supplied in 1/2 circle, 1/4 circle or other configuration
if desired.
Column
covers can be fluted vertically or horizontally as desired, for design effect
and/or to facilitate installation, as well as insulated where columns are
located at mid-exterior wall (half inside, half outside). Snap-in flute inserts
can be provided in a range of colours, or matching finishes.
Using internal members is the most common method of stiffining
and fastening of column covers. Requirements for these members e.g. supports,
fastening angles, alignment bars, subgirts, brackets, clips, inserts, shims,
etc. depend largely on the size and shape of the column. Generally galvanized
steel is used f
|
| Finishes: |
The following aluminum finishes are offered as standard by
Kanalco:
Stainless Steel: 1. X-L Blend "S" (Excelsior) - for typical architectural
applications. 2. X-L
Buff (AISI #8) - for a mirror-like appearance. 3. No. 4 (Excelsior) brushed finish. Other finishes available upon request.
Aluminum: 1. AA-A31 adonized Class 1, 18 um (.0007") or class 2, 10 um (.0004")
finish in clear or range of manufacturer's standard architectural colours.
2. Duranar® fluoro-polymer enamel coating with Kynar 500* resin in a
wide range of architectural colors.
® Duranar is a registered trademark of PPG
Industries, Inc. * Kynar 500 is a registered trademark of Pennwalt
Corporation.
|
| Accessories |
1.
Galvanized steel brackets or supports as detailed or required. 2. Glass fibre insulation of thickness,
density and thermal value as required. 3. Snap-in flute inserts in accent colours, or matching
finish.
|
| Sizes: |
Section widths or round column radius: as desired
Length: (in one
piece - 3.6 m (12'-0")(in sections - unlimited)
Thickness: Stainless Steel - 1.5 mm (.062") is standard. Other
thicknesses available. Aluminum - 3mm (.125") is standard. Other thicknesses
available. Radiused
Corners - 6 mm (1/4") minimum
|
| Shapes: |
Brake or roll (roller die) forming can produce round, square or
rectangular, angular or other shapes as desired. Kanalco can
advise on proposed design configurations upon request.
|
Applicable Standards: |
Kanalco metal fabrications conform to: ASTM A240 for Type 304 stainless steel.
Aluminum Association
Designation System for Aluminum Finishes. AAMA (Architectural Aluminum
Manufacturers Association) 605 test requirements for finishes. CSA G164-M 1981 or ASTM A123-84 for
galvanizing of steel brackets or supports, etc. CSA W59-1989 for corner or other type
welds.
|
TECHNICAL DATA |
Consult with Kanalco Ltd.
|
| INSTALLATION |
Methods: Kanalco Ltd. are a custom manufacturer
specializing in the metal fabrications field. Installation of
Kanalco stainless steel and aluminum products is normally carried
out by the appropriate trades and experienced installers according to
specifications and approved shop drawings.
|
AVAILABILITY & COSTS |
Kanalco fabricated metal products can be shipped
anywhere in North America. Current cost data is available upon request.
|
| WARRANTY |
Normal 1 year construction warranty.
|
| MAINTENANCE |
For
stainless steel and aluminum finishes, in most instances, only a periodic warm
water wash and drying with a soft cloth is sufficient to restore the original
lustre.
However,
depending on the severity of dirt accumulation, more elaborate cleaning
procedures may be required. Consult with Kanalco for additional data.
In the case of
mirror-like stainless steel finishes, e.g. X-L Buff, the foregoing is still
applicable however commercial creams are available which provide added lustre
to these finishes.
|
TECHNICAL SERVICES |
Kanalco Ltd. can provide consultation from preliminary
design through to product application, including the following:
 |
Technical
advice for both new work and retrofit applications. |
 |
Finish
samples. |
 |
Specification assistance. |
 |
Shop
drawings. |
 |
Recommending contractor sources. |
 |
Site
advice and recommendations |
|
| RELATED REFERENCES |
Additional Kanalco Ltd. MANU-DATA technical literature:
- Stainless Steel
Wall Panels - Aluminum
Wall Panels -
Speciality Sheet Metal Fabrication - Insulated Panels
|
| SPECIFICATION |
SPEC
NOTE: The following material and fabrication clauses are arranged for inclusion
in the "Sheet Metal Fabrications" or "Manufactured Wall Panels" specification
Sections using the CSC/CSI 3-Part Section Format. Square brackets [ ] indicate
alternatives, data required or need for the specifier to make a decision.
1
MATERIALS Column
Covers Preformed
[stainless steel] [aluminum] column covers as manufactured by Kanalco
Ltd. and as follows:
A) Stainless Steel: Type 304 to ASTM
A240, [1.5 mm (.062")] thick with [X-L Blend "S" (Excelsior)] [X-L Buff
(AISI #8)] [#4(Excelsior)] finish .
B) Aluminum: [_____] alloy aluminum sheet to AA
and AAMA requirements, 3mm (.125") thick, with architectural [Class 1, 18
um (.0007")] [Class 2, 10 um (.0004)] [clear anodized] [color
anodized] AA-A31 finish [_____color as selected.]
OR
Kynar 500 finish [_____]color as selected. C) Screws: stainless steel to CSA
B35.3-1962.
D)
Gaskets: closed cell polyurethane foam, adheasive on two sides, release
paper protected.
E) Sealents: in accordance with Section 07 [_____], paragraph
[_____], [_____] colour selected by [Consultant] [Engineer].
F) Isolation
coating: [alkali resistant] [bituminous paint] [epoxy resin solution].
G) Galvanized
steel brackets, liner sheet, etc.: hot dipped galvanizing [600] g/m2 [(3.4 mils)] to CSA G164-M1981 or ASTM A123-84.
H)
Insulation: glass fibre, density [_____kg/m3
(_____psf)], flame spread [25], permeance 28.75 lvanizing ng/(Pa.s.m2)
(_____perms), [RSI-(R)] indicated. with z
J) Insulation adheasive: compatible with type of
insulation and [zinc coated steel], uncombustible after curing. g [0]
g/m
.2
FABRICATION
1
Fabricate wall panels in accordance with specifications and approved shop
drawings. 2 Maximum
allowable fabrication tolerences to be: A) Panel bow: 0.2% of panel dimensions up to 0.187"
maximum.
B) Width
or length: + 0.80 mm (0.032") up to 1220 mm (48") + 1.5 mm (0.064") from 1220
mm to 3360 mm (48" to 144"). C) Squreness: Maximum 4.7 mm (0.187") difference between diagonal
measurements.
3
Form all panels to specified dimensions with tolerences to accomodate thermal
expansion and contraction between panels and structural members. Accurately
form radii of curved panels in plant.
4 Factory fabricate accessory and trim components, ready
for installation.
|